CalcTrace

Staircase Rise, Run and Stringer Calculator

Set out a straight flight of stairs. Enter the height from floor to floor and either a target riser height and going, or the horizontal space you have. The calculator gives the number of risers and treads, the actual riser, the total run, the stringer length and the angle, and checks 2R + G, the riser and the going against limits you can edit.

Last updated .

Your stairs

Units
mm
Work from
mm
mm

Risers = total rise ÷ target, rounded to the nearest whole number, so the actual riser can be a little above or below the target. The going is measured from nosing to nosing, without the overhang.

Treads = risers − 1. This assumes the upper floor (or a landing) is the top tread, so there is no separate tread level with it.

Comfort range for 2R + G
mm
mm
Riser height limits
mm
mm
Going limits
mm
mm

Editable defaults: check your local code. The default figures are the National Construction Code (Australia) limits for most stairways (2R + G 550 to 700 mm, riser 115 to 190 mm, going 240 to 355 mm). Other stair types, other buildings and other countries can have different limits, and codes also cover headroom, landings, handrails, balustrades and open risers, which are not checked here.

Result

Your stairValue
Checks against your limits
CheckYoursLimitsResult
Nearby options
RisersRiserGoing2R + GAngle

Geometry only. Dimensions are from finished floor to finished floor and nosing to nosing; allow for floor coverings and tread thickness. The stringer length is the straight diagonal of the total rise and run; the board you buy must be longer to allow for the cuts at each end.

Show the working

    How a straight flight is set out

    Every step in a flight should be the same, so the total rise is divided into equal risers. Start from the riser height you are aiming for and round to a whole number of risers:

    n = round(H ÷ T)   R = H ÷ n   treads = n − 1

    H is the total rise from finished floor to finished floor, T the target riser height, n the number of risers and R the actual height of each riser. In a straight flight that ends at the upper floor, the upper floor itself is the last tread, so there is one fewer tread than risers. That is the assumption this calculator makes.

    Total run = (n − 1) × G

    G is the going: the horizontal depth of one step from nosing to nosing. If you work from the space available instead, the going follows from it: G = run ÷ (n − 1).

    Stringer length = √(H² + run²)   Angle = atan(R ÷ G)

    The stringers are the sloping boards that carry the treads. The first formula is Pythagoras' theorem applied to the whole flight: the diagonal from the foot of the bottom riser to the edge of the upper floor. It is the minimum length of the sloping part; the board itself must be longer for the plumb and level cuts at each end. The angle is the pitch of the stair, set by one riser and one going.

    Comfort rule: 2R + G between a lower and upper limit

    The rule ties riser and going to the length of a walking stride: climbing one riser takes about twice the effort of moving one going on the level, so two risers plus one going should add up to roughly one comfortable pace. The idea is usually credited to the 17th-century French architect François Blondel. The default range of 550 to 700 mm is the 2R + G range in the National Construction Code (NCC) of Australia, which also limits risers to 115 to 190 mm and goings to 240 to 355 mm for most stairways. All six figures are editable because other stair types and other countries' codes differ: check the code that applies where you are building.

    Worked example: 2,700 mm rise, 175 mm target riser

    1. Number of risers. 2,700 ÷ 175 = 15.43, rounded to 15 risers.
    2. Actual riser. R = 2,700 ÷ 15 = 180 mm, within 115 to 190 mm.
    3. Treads. 15 − 1 = 14 treads.
    4. Total run. With a 250 mm going, 14 × 250 = 3,500 mm.
    5. Stringer length. √(2,700² + 3,500²) = 4,420.4 mm.
    6. Angle. atan(180 ÷ 250) = 35.75°.
    7. Comfort check. 2 × 180 + 250 = 610 mm, inside 550 to 700 mm.

    Rounding to the nearest whole number can give a riser a little taller than the target. A 190 mm target on the same rise gives 2,700 ÷ 190 = 14.21, rounded to 14 risers of 192.86 mm, which is above the 190 mm default limit; the check flags it, and adding one riser (15 of 180 mm) fixes it.

    Working from the space available

    With the same 2,700 mm rise and 3,600 mm of run, the calculator tries each number of risers and keeps the one whose 2R + G is closest to the middle of the range, 625 mm. Fifteen risers give R = 180 mm and G = 3,600 ÷ 14 = 257.14 mm, so 2R + G = 617.14 mm and the angle is 34.99°. The stringer is √(2,700² + 3,600²) = 4,500 mm. Fourteen risers would give R = 192.86 mm, over the default riser limit, and sixteen give R = 168.75 mm with G = 240 mm, right at the minimum going, and 2R + G = 577.5 mm.

    In inches

    A 108 in rise with a 7.5 in target needs 108 ÷ 7.5 = 14.4, rounded to 14 risers of 7.71 in. With a 10.5 in going there are 13 treads, a run of 13 × 10.5 = 136.5 in and 2R + G = 25.93 in. In inches the default limits are 21.65 to 27.56 in for 2R + G, 4.53 to 7.48 in for the riser and 9.45 to 13.98 in for the going.

    Common mistakes

    Measuring to the subfloor. The total rise must be between finished surfaces. If 20 mm of tiles go on the lower floor but not the upper one, the bottom riser ends up 20 mm short unless you allow for it, and an odd step is a trip hazard.

    Counting treads and risers as equal. In a flight that stops at the upper floor there are n risers and n − 1 treads. Using n treads makes the stair one going too long.

    Rounding the riser and then multiplying. 2,700 ÷ 16 = 168.75 mm. Rounding to 169 mm and marking out 16 risers adds 4 mm by the top. Mark out from a running total, or set a stair gauge to the exact figure.

    Forgetting headroom and landings. This calculator handles one straight flight. Headroom over the stair, landing sizes, handrails, balustrades and the gaps between them are all set by building codes and are not checked here.