How the payback is worked out
The calculator follows one year at a time for 25 years. Each year it works out how much the panels generate, splits that between power used in the home and power exported, and values each part at its own rate.
Gn = P × g × 365 × (1 − d)n − 1
Gn is generation in year n in kWh, P the system size in kW, g the daily generation per kW in kWh/kW/day, and d the yearly panel degradation as a decimal. Degradation is compounded, so year 1 is at full output and each later year is a fixed percentage below the one before.
Sn = Gn × s × pn + Gn × (1 − s) × fn
s is the share used in the home, pn the electricity price and fn the feed-in tariff in year n, both in dollars per kWh. Each solar kWh used in the home is one you did not buy, so it is worth the full price; an exported kWh earns only the feed-in tariff. Prices grow as pn = p1 × (1 + r)n − 1, with r the yearly rise, and the feed-in tariff the same way with its own rate.
Simple payback = C ÷ S1 Net position after n years = S1 + … + Sn − C
C is what you pay, after rebates, plus any battery. Simple payback uses year-1 savings only. The year the net position turns positive uses the full table, so it picks up price rises and degradation.
The STC discount
Under the Small-scale Renewable Energy Scheme, a system creates small-scale technology certificates (STCs), and installers usually take them in exchange for a lower price. The estimate is:
STCs = P × zone rating × deeming period, counted in whole certificates
The zone ratings are set by the Renewable Energy (Electricity) (Zone Ratings and Zones for Solar (Photovoltaic) Systems) Instrument 2019, in the Clean Energy Regulator's postcode table dated 1 January 2020: zone 1 is 1.622, zone 2 is 1.536, zone 3 is 1.382 and zone 4 is 1.185. The Regulator's page on calculating STC entitlements (updated 29 October 2026) gives a deeming period of 5 years for 2026 installs, falling by one year each year: 4 in 2027, down to 1 in 2030 when the scheme ends. Sydney (2000), Brisbane (4000), Perth (6000), Adelaide (5000) and Canberra (2600) are zone 3, Melbourne (3000) and Hobart (7000) zone 4, and Darwin (0800) zone 2. The STC price is a market price, so the $38 default is only an example. The REC Registry calculator gives the official certificate count.
The default daily generation comes from the same table: a zone rating is MWh per kW for each deemed year, so zone 3 gives 1,382 kWh ÷ 365 = 3.79 kWh/kW/day. Zone 1 gives 4.44, zone 2 4.21 and zone 4 3.25. These are averages for a whole zone, not a forecast for your roof.
Worked example: 6.6 kW in Sydney
- Generation. 6.6 × 3.79 × 365 = 9,130.11 kWh in year 1.
- Split. 30% used at home is 2,739.03 kWh; the other 6,391.08 kWh is exported.
- Savings. 2,739.03 × $0.30 = $821.71, plus 6,391.08 × $0.05 = $319.55, so $1,141.26 in year 1.
- Simple payback. $6,000 ÷ $1,141.26 = 5.26 years.
- Year by year. With 0.5% degradation and a 3% price rise, year 2 generates 9,084.46 kWh and saves $1,160.09. After 5 years the cumulative savings are $5,899.75, still $100.25 short; after year 6 they reach $7,140.41, so the net position turns positive in year 6.
- 25 years. Year 25 generates 8,095.24 kWh at a price of 60.98 c/kWh. Savings total $35,540.70 and the net position is $29,540.70. With no price rise, the total is $26,883.55.
- STCs. 6.6 × 1.382 × 5 = 45.61, so 45 whole certificates. At the example $38 each that is $1,710.
Adding a battery for an example $10,000 and lifting home use to 70% makes year-1 savings 9,130.11 × 0.7 × $0.30 + 2,739.03 × $0.05 = $2,054.27. The cost is now $16,000, so simple payback is 7.79 years and the net position turns positive in year 8.
How to read the result
Self-consumption drives the answer. When the feed-in tariff is far below the price you pay, each kWh used at home is worth several exported ones. Running a dishwasher, pool pump or hot water system in the middle of the day can shorten payback more than a bigger system.
Your roof matters more than your city. A north-facing roof at a sensible tilt does better than one facing east or west, and shade from trees, chimneys or a neighbour's building can cut output sharply. Replace the default with your installer's site estimate whenever you have one.
Tariffs move. Time-of-use pricing, daily supply charges and retailer plan changes are not modelled. The price rise and feed-in change are assumptions; try a few values to see how sensitive the answer is.
What is left out. There is no discounting for the time value of money, no inverter replacement, no cleaning or maintenance cost, and no battery wear or replacement. Batteries usually wear out sooner than panels, so a 25-year battery figure is optimistic. Results are an estimate, not advice to buy any product.