The Magnus formula
Air can hold only so much water vapour before it condenses, and that limit rises steeply with temperature. The limit is described by the saturation vapour pressure, the pressure the vapour exerts when the air is saturated. Relative humidity is the actual vapour pressure as a percentage of that limit. The dew point is the temperature to which the air would have to cool, with its moisture unchanged, for the actual vapour pressure to become the saturation value.
es(T) = 6.1094 × exp[17.625 T ÷ (T + 243.04)]
This is the Magnus form of the saturation vapour pressure, es in hectopascals (hPa) and T in °C. The three coefficients, a = 6.1094 hPa, b = 17.625 and c = 243.04 °C, are the ones recommended by Oleg Alduchov and Robert Eskridge in “Improved Magnus Form Approximation of Saturation Vapor Pressure” (Journal of Applied Meteorology, 1996). Turning the formula round gives the dew point:
γ = ln(RH ÷ 100) + b T ÷ (c + T)
Td = c γ ÷ (b − γ)
RH is the relative humidity in per cent, ln the natural logarithm and Td the dew point in °C. The reverse, relative humidity from the temperature and dew point, is the ratio of the two saturation pressures:
RH = 100 × exp[b Td ÷ (c + Td) − b T ÷ (c + T)]
Accuracy and range
Alduchov and Eskridge fitted these coefficients for temperatures from −40 °C to 50 °C, and over that range they report a relative error in the saturation vapour pressure below 0.4%. Converted to a dew point, that is about a tenth of a degree or less, far smaller than the error of most household humidity sensors. The calculator warns when a temperature or dew point is outside that range. The formula is for vapour over liquid water. Below 0 °C, moisture usually deposits as frost, and the frost point is a little higher than the dew point given here.
Worked example
Air at 25 °C with 60% relative humidity:
- Humidity term. ln(60 ÷ 100) = ln(0.6) = −0.5108.
- Temperature term. 17.625 × 25 ÷ (243.04 + 25) = 440.625 ÷ 268.04 = 1.6439.
- Add them. γ = −0.5108 + 1.6439 = 1.1331.
- Dew point. Td = 243.04 × 1.1331 ÷ (17.625 − 1.1331) = 275.39 ÷ 16.4919 = 16.7 °C.
The air would have to cool by about 8.3 degrees before dew forms. Its saturation vapour pressure is 31.62 hPa and the actual vapour pressure 60% of that, 18.97 hPa.
Going the other way, air at 30 °C with a dew point of 20 °C has a relative humidity of 100 × exp(1.3401 − 1.9365) = 55.1%.
A quick mental check comes from Mark Lawrence (Bulletin of the American Meteorological Society, 2005): when the relative humidity is above about 50%, the dew point is roughly the temperature minus (100 − RH) ÷ 5. For the example, 25 − 40 ÷ 5 = 17 °C, close to the exact 16.7 °C.
What the dew point says about comfort
Relative humidity alone is a poor guide to how muggy it feels, because it depends on the temperature as much as on the moisture. On a typical day the amount of water vapour hardly changes, yet the relative humidity is high at dawn and falls in the afternoon simply because the air has warmed. The dew point does not move with the temperature in that way: it measures the moisture itself.
For comfort, the useful idea is that the body cools by evaporating sweat, and evaporation slows as the air’s vapour pressure gets closer to that of moist skin. So the higher the dew point, the less effective sweating becomes and the stickier the air feels, whatever the relative humidity reading. Two days at the same temperature feel different mainly because of their dew points. People differ in what they find comfortable, so this page does not give fixed comfort bands.
The gap between the temperature and the dew point is also practical. When it is small, a cool surface such as a cold drink, a window or a car windscreen will collect condensation, and on a still, clear night fog or dew is likely as the air cools towards the dew point.
Common mistakes
- Using relative humidity from a different temperature. Humidity and temperature must be measured together; the dew point of indoor air is not the outdoor one.
- A dew point above the temperature. That would mean more than 100% humidity, which is not possible in a stable reading, so the calculator rejects it.